Facilities in Electrical Testing discipline |
1. Domestic Electrical Appliances |
Electric Iron/Steam Iron (IS: 366, IS: 302-2-3) |
| * |
Classification |
| * |
Power Input and Current |
| * |
Temperature rise/ Heating |
| * |
Leakage Current and Electric Strength at Operating Temperature |
| * |
Transient Overvoltage |
| * |
Moisture Resistance |
| * |
Leakage Current and Electric Strength |
| * |
Abnormal Operation |
| * |
Stability and Mechanical Hazards |
| * |
Mechanical Strength |
| * |
Components |
| * |
Construction |
| * |
Supply Connection and External Flexible Cords |
| * |
Terminals for External Conductors |
| * |
Provision for Earthing |
| * |
Screws and Connections |
| * |
Clearances, Creepage Distances and Solid Insulation |
| * |
Resistance to Heat and Fire |
| * |
Resistance to Rusting |
| * |
Measurement of Heating-up Time |
| * |
Measurement of Sole Plate Temperature |
| * |
Measurement of Temperature Distribution |
| * |
Measurement of Initial Overswing Temperature and Heating-up excess Temperature |
| * |
Measurement of Cyclic Fluctuation of Temperature |
| * |
Measurement of Thermostatic Stability |
| * |
Finish |
Electric Immersion Water Heater (IS: 368, IS: 302-2-201) |
| * | Classification |
| * | Marking and Instructions |
| * | Protection against Access to Live Parts/ Protection against Electric Shock |
| * | Power input and Current |
| * | Temperature rise/ Heating |
| * | Operation under Overload Conditions of Appliances with Heating Element |
| * | Leakage Current and Electric Strength at Operating Temperature |
| * | Transient Overvoltage |
| * | Moisture Resistance |
| * | Leakage Current and Electric Strength |
| * | Endurance |
| * | Abnormal Operation |
| * | Stability and Mechanical Hazards |
| * | Mechanical Strength |
| * | Construction |
| * | Internal Wiring |
| * | Components |
| * | Supply Connection and External Flexible Cords |
| * | Terminals for External Conductors |
| * | Provision for Earthing |
| * | Screws and Connections |
| * | Clearances, Creepage Distances and Solid Insulation |
| * | Resistance to Heat and Fire |
| * | Resistance to Rusting |
Electric Radiator (IS: 369, IS: 302-2-30) |
| * | Classification |
| * | Marking and Instructions |
| * | Protection against Access to Live Parts/ Protection against Electric Shock |
| * | Power Input and Current |
| * | Temperature rise/ Heating |
| * | Leakage Current and Electric Strength at Operating Temperature |
| * | Transient Overvoltage |
| * | Moisture Resistance |
| * | Leakage Current and Electric Strength |
| * | Abnormal Operation |
| * | Stability and Mechanical Hazards |
| * | Mechanical Strength |
| * | Construction |
| * | Internal Wiring |
| * | Components |
| * | Supply Connection and External Flexible Cords |
| * | Terminals for External Conductors |
| * | Provision for Earthing |
| * | Screws and Connections |
| * | Clearances, Creepage Distances and Solid Insulation |
| * | Resistance to Heat and Fire |
| * | Clearances, Creepage Distances and Solid Insulation |
| * | Resistance to Heat and Fire |
| * | Resistance to Rusting |
| * | Dimensions |
| * | Temperature rise of surface on which Iron is placed or supported |
| * | Endurance Test |
| * | Finish |
Electric Instantaneous Water Heater (IS: 8978, IS: 302-2-35) |
| * | Classification |
| * | Marking and Instructions |
| * | Protection against Access to Live Parts/ Protection against Electric Shock |
| * | Power input and Current |
| * | Temperature rise/ Heating |
| * | Leakage Current and Electric Strength at Operating Temperature |
| * | Transient Overvoltage |
| * | Moisture Resistance |
| * | Leakage Current and Electric Strength |
| * | Abnormal Operation |
| * | Stability and Mechanical Hazards |
| * | Mechanical Strength |
| * | Construction |
| * | Internal Wiring |
| * | Components |
| * | Supply Connection and External Flexible Cords |
| * | Terminals for External Conductors |
| * | Provision for Earthing |
| * | Screws and Connections |
| * | Clearances, Creepage Distances and Solid Insulation |
| * | Resistance to Heat and Fire |
| * | Resistance to Rusting |
| * | Finish |
| * | Operation of Flow Switch |
| * | Endurance Test |
Electric Kettle & Jugs (IS: 367, IS: 302-2-15) |
| * | Classification |
| * | Marking and Instructions |
| * | Protection against Access to Live Parts/ Protection against Electric Shock |
| * | Power input and Current |
| * | Temperature rise/ Heating |
| * | Leakage Current and Electric Strength at Operating Temperature |
| * | Transient Overvoltage |
| * | Moisture Resistance |
| * | Leakage Current and Electric Strength |
| * | Abnormal Operation |
| * | Stability and Mechanical Hazards |
| * | Mechanical Strength |
| * | Construction |
| * | Internal Wiring |
| * | Components |
| * | Supply Connection and External Flexible Cords |
| * | Terminals for External Conductors |
| * | Provision for Earthing |
| * | Screws and Connections |
| * | Clearances, Creepage Distances and Solid Insulation |
| * | Resistance to Heat and Fire |
| * | Resistance to Rusting |
Electric Toasters, Electric Grills and Roastes (IS: 1287, IS: 302-2-9) |
| * | Classification |
| * | Marking and Instructions |
| * | Protection against Access to Live Parts/ Protection against Electric Shock |
| * | Power input and Current |
| * | Temperature rise/ Heating |
| * | Leakage Current and Electric Strength at Operating Temperature |
| * | Transient Overvoltage |
| * | Moisture Resistance |
| * | Leakage Current and Electric Strength |
| * | Abnormal Operation |
| * | Stability and Mechanical Hazards |
| * | Mechanical Strength |
| * | Construction |
| * | Internal Wiring |
| * | Components |
| * | Supply Connection and External Flexible Cords |
| * | Terminals for External Conductors |
| * | Provision for Earthing |
| * | Screws and Connections |
| * | Clearances, Creepage Distances and Solid Insulation |
| * | Resistance to Heat and Fire |
| * | Resistance to Rusting |
Domestic Electric Food Mixers (IS: 4250, IS: 302-2-14) |
| * | Classification |
| * | Marking and Instructions |
| * | Protection against Access to Live Parts/ Protection against Electric Shock |
| * | Power input and Current |
| * | Temperature rise/ Heating |
| * | Leakage Current and Electric Strength at Operating Temperature |
| * | Transient Overvoltage |
| * | Moisture Resistance |
| * | Leakage Current and Electric Strength |
| * | Endurance Test |
| * | Abnormal Operation |
| * | Stability and Mechanical Hazards |
| * | Mechanical Strength |
| * | Construction |
| * | Internal Wiring |
| * | Components |
| * | Supply Connection and External Flexible Cords |
| * | Terminals for External Conductors |
| * | Provision for Earthing |
| * | Screws and Connections |
| * | Clearances, Creepage Distances and Solid Insulation |
| * | Resistance to Heat and Fire |
| * | Resistance to Rusting |
| * | Operational Tests |
| * | Temperature withstand Test for Bowl |
| * | Test for Controls |
| * | Strength of Assembly |
2. Measuring Instruments |
Electrical Load Cell (IS 9281 (Part III)) |
| * | Performance Requirements |
| * | Mode of Operation |
| * | Input resistance/ Impedence |
| * | Output resistance/ Impedence |
| * | Input voltage/ Current (max) |
| * | Overload safe |
| * | Overload ultimate |
| * | Accuracy |
| * | Rated output voltage and Tolerance |
| * | No load output |
| * | Drift in no load output (Zero drift) after 1 hour of warm-up |
| * | Instability of RO after warm-up period of 1 hour |
| * | Non-linearity |
| * | Hysteresis |
| * | Non-repeatability of zero output |
| * | Non-repeatability of rated output |
| * | Creep at rated load after 30 minutes |
| * | Creep recovery after 10 minutes |
| * | Concentric angular loading error at 1˚ inclination |
| * | Concentric angular loading error at 3˚ inclination |
| * | Eccentric loading error at 1 mm of eccentricity |
| * | Eccentric loading error at 1 mm of eccentricity and 1˚ inclination |
| * | Eccentric loading error at 1 mm of eccentricity and 3˚ inclination |
| * | Temperature effect on no load output |
| * | Temperature effect on rated output |
| * | Insulation resistance |
| * | Dimension, weight |
Electronic Weighing Systems (IS 9281 (Part III)) |
| * | Accuracy |
| * | Non linearity |
| * | Drift of no load output with temperature |
| * | Drift of no load output with time after 1h |
| * | Drift of full scale output with time after 1h |
| * | Internal calibration |
| * | Number of Scale division |
| * | Resolution |
| * | Tare provision |
| * | Display |
| * | Recording |
| * | Overload indication |
| * | Operating Temperature |
| * | Weight |
| * | Dimensions |
| * | Tolerance on operating voltage |
3. Environmental Testing Facility |
All Electrical Products Equipment and Subassemblies |
| * | Cold Test – IS 9000 (Part 2) Sec 1 to 4 |
| * | Dry Heat Test – IS 9000 (Part 3) Sec 1 to 5 |
| * | Damp Heat (Cyclic) Test –IS 9000 (Part 5) Sec 1 & 2 |
| * | Damp Heat (Steady State) Test – IS 9000 (Part 4) |
| * | Vibration Test – IS 9000 (Part 8) |
| * | Shock Test – IS 9000 (Part 7) Sec 1 |
| * | Degree of Protection Provided by Enclosures (IP Code) Dust- IS/IEC 60529 |
| * | Degree of Protection Provided by Enclosures (IP Code) Water- IS/IEC 60529 |